BQYSC - 717 BICARBONATE
- MSDS: BQYSC
- Manufacturer: BOEHRINGER MANNHEIM CORP
- Product Name: 717 BICARBONATE
- National Stock Number: 6550-00F026922
Product Identification
Product ID:717 BICARBONATE
MSDS Date:11/10/1989
FSC:6550
NIIN:00F026922
MSDS Number: BQYSC
Responsible Party
INDIANAPOLIS, IN 46250
US
Emergency Phone: 317-845-2000/317-845-2684
Info Phone: 317-845-2000/317-845-2684
Cage: 32239
Contractor
Telephone: 317-845-2000
Cage: 32239
Ingredients
GLYCERINE, 1,2,3,-TRIHYDROXYPROPANE, GLYCEROL, ANHYDROUS
CAS: 56-81-5
RTECS: MA8050000
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 (MIST) 9293
SODIUM HYDROXIDE, CAUSTIC SODA, LYE
CAS: 1310-73-2
RTECS: WB4900000
Fraction By Weight: 25-30%
OSHA PEL 2 MG/M3
ACGIH TLV: C 2 MG/M3; 9293
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN: IRRITATION. INGESTION: MILDLY
TOXIC, SYSTEMIC EFFECTS INCLUDE HEADACHE, NAUSEA & VOMITING. EYE:
IRRITATION. INHALATION: IRRITATION. POSION BY SUBCUTANEOUS ROUTE.
Explanation of Carcinogenicity:NONE
First Aid
First Aid:EYE: PROMPTLY FLUSH W/WATER FOR AT LEAST 15 MINS. INGESTION:
KEEP VICTIM WARM & CALM. SKIN: IMMEDIATELY BEGIN FLUSHING AFFECTED
BODY AREA W/LARGE AMOUNTS OF FRESH WATER FOR AT LEAST 15 MINS.
INHALATIO N: REMOVE TO FRESH AIR. IF BREATHING BECOMES LABORED OR
STOPS, USE OXYGEN OR ARTIFICIAL RESPIRATION FOR THE RESPECTIVE
CONDITIONS. OBTAIN MEDICAL ATTENTION IN ALL CASES.
Fire Fighting
Flash Point:320F
Extinguishing Media:ALCOHOL FOAM, CO2, DRY CHEMICALS
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS & THE
APPROPRIATE ENCAPSULATORY PROTECTIVE GARMENTS. IF POSSIBLE, ATTEMPT
TO MOVE THIS PRODUCT AWAY FROM FIRE SCENE.
Unusual Fire/Explosion Hazard:MAY BE COMBUSTIBLE WHEN EXPOSED TO HEAT
OR FLAMES.
Accidental Release
Spill Release Procedures:EVACUATE & VENTILATE AREA. INITIATE CLEAN UP.
IF PRODUCT IS DRY, SWEEP UP, PLACE IN SUITABLE CONTAINER, SEAL,
LABEL, & HOLD FOR DISPOSAL. IF IN A SOLUTION USE ABSORBENT MATERIAL
TO CONTAIN/PICK UP SPI LLED SOLUTION. UPON COMPLETION WASH SITE
W/WATER.
Handling
Handling and Storage Precautions:STORE IN COOL DRY PLACE. STORE IN A
SEALED CONDITION. DON'T MOUTH PIPETTE. USE GOOD LABORATORY
PRACTICES WHEN HANDLING THIS PRODUCT.
Other Precautions:PEPC, A ENZYMATICALLY ACTIVE MATERIAL, SHOULD BE
HANDLED W/CARE. AS W/MOST MATERIALS OF THIS TYPE, INDIVIDUAL
SENSITIZATION IS POSSIBLE.
Exposure Controls
Respiratory Protection:AN ACID GAS RESPIRATOR W/A DUST/MIST PREFILTER
IS NEEDED. USE SCBA IF NEEDED.
Ventilation:CHEMICAL FUME HOOD
Protective Gloves:RUBBER
Eye Protection:CHEMICAL SAFETY GOGGLES
Other Protective Equipment:DELUGE SHOWERS & EYEWASH STATION, LAB COAT,
ENCAPSULATORY GARMENTS ARE NEEDED.
Work Hygienic Practices:REMOVE & WASH CONTAMINATED CLOTHES BEFORE
REUSE. DON'T EAT/DRINK/SMOKE WHEN HANDLING THIS PRODUCT. WASH
THOROUGHLY
Supplemental Safety and Health
Chemical Properties
Boiling Pt:B.P. Text:554F
Vapor Pres:0.0025
Spec Gravity:1.26
Appearance and Odor:LIQUID GREENISH HUE
Stability
Stability Indicator/Materials to Avoid:YES
STRONG ACIDS, CHLORINE, LEAD, CHROMIUM, FLUORIDE, POTASSIUM, SILVER
Stability Condition to Avoid:HEAT, FLAME OR POWERFUL OXIDIZERS
Hazardous Decomposition Products:ACRID SMOKE & FUMES
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE W/FEDERAL, STATE &
LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.